Arthrex Inc knotless fibertak anchors
The left hip of the same patient in after circumferential labral reconstruction using an allograft (G) and 1.8mm Knotless <t>FiberTak</t> anchors (Arthrex) to perform the knotless pull-through technique. View was from the anterolateral (12 o’clock) portal with a 70 arthroscope. (a) Under traction, the most medial point of fixation of the reconstruction site, was identified (M). (b) The arthroscope was moved laterally, the 12 o’clock position was identified (*). (c) Bird’s eye arthroscopic view of the fixated labral reconstruction graft (G). (d) Hip traction was released, restoration of the labral seal was noted (*). A, acetabulum; FH, femoral head; G, graft.
Knotless Fibertak Anchors, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/knotless fibertak anchors/product/Arthrex Inc
Average 86 stars, based on 1 article reviews
knotless fibertak anchors - by Bioz Stars, 2026-06
86/100 stars

Images

1) Product Images from "High rate of graft integration after acetabular labral reconstruction with the knotless pull-through technique "

Article Title: High rate of graft integration after acetabular labral reconstruction with the knotless pull-through technique

Journal: Journal of Hip Preservation Surgery

doi: 10.1093/jhps/hnaf036

The left hip of the same patient in after circumferential labral reconstruction using an allograft (G) and 1.8mm Knotless FiberTak anchors (Arthrex) to perform the knotless pull-through technique. View was from the anterolateral (12 o’clock) portal with a 70 arthroscope. (a) Under traction, the most medial point of fixation of the reconstruction site, was identified (M). (b) The arthroscope was moved laterally, the 12 o’clock position was identified (*). (c) Bird’s eye arthroscopic view of the fixated labral reconstruction graft (G). (d) Hip traction was released, restoration of the labral seal was noted (*). A, acetabulum; FH, femoral head; G, graft.
Figure Legend Snippet: The left hip of the same patient in after circumferential labral reconstruction using an allograft (G) and 1.8mm Knotless FiberTak anchors (Arthrex) to perform the knotless pull-through technique. View was from the anterolateral (12 o’clock) portal with a 70 arthroscope. (a) Under traction, the most medial point of fixation of the reconstruction site, was identified (M). (b) The arthroscope was moved laterally, the 12 o’clock position was identified (*). (c) Bird’s eye arthroscopic view of the fixated labral reconstruction graft (G). (d) Hip traction was released, restoration of the labral seal was noted (*). A, acetabulum; FH, femoral head; G, graft.

Techniques Used:



Similar Products

86
Arthrex Inc knotless fibertak anchors
The left hip of the same patient in after circumferential labral reconstruction using an allograft (G) and 1.8mm Knotless <t>FiberTak</t> anchors (Arthrex) to perform the knotless pull-through technique. View was from the anterolateral (12 o’clock) portal with a 70 arthroscope. (a) Under traction, the most medial point of fixation of the reconstruction site, was identified (M). (b) The arthroscope was moved laterally, the 12 o’clock position was identified (*). (c) Bird’s eye arthroscopic view of the fixated labral reconstruction graft (G). (d) Hip traction was released, restoration of the labral seal was noted (*). A, acetabulum; FH, femoral head; G, graft.
Knotless Fibertak Anchors, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/knotless fibertak anchors/product/Arthrex Inc
Average 86 stars, based on 1 article reviews
knotless fibertak anchors - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

86
Arthrex Inc fibertak triple loaded anchors
The left hip of the same patient in after circumferential labral reconstruction using an allograft (G) and 1.8mm Knotless <t>FiberTak</t> anchors (Arthrex) to perform the knotless pull-through technique. View was from the anterolateral (12 o’clock) portal with a 70 arthroscope. (a) Under traction, the most medial point of fixation of the reconstruction site, was identified (M). (b) The arthroscope was moved laterally, the 12 o’clock position was identified (*). (c) Bird’s eye arthroscopic view of the fixated labral reconstruction graft (G). (d) Hip traction was released, restoration of the labral seal was noted (*). A, acetabulum; FH, femoral head; G, graft.
Fibertak Triple Loaded Anchors, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fibertak triple loaded anchors/product/Arthrex Inc
Average 86 stars, based on 1 article reviews
fibertak triple loaded anchors - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

86
Arthrex Inc fibertak anchor
The left hip of the same patient in after circumferential labral reconstruction using an allograft (G) and 1.8mm Knotless <t>FiberTak</t> anchors (Arthrex) to perform the knotless pull-through technique. View was from the anterolateral (12 o’clock) portal with a 70 arthroscope. (a) Under traction, the most medial point of fixation of the reconstruction site, was identified (M). (b) The arthroscope was moved laterally, the 12 o’clock position was identified (*). (c) Bird’s eye arthroscopic view of the fixated labral reconstruction graft (G). (d) Hip traction was released, restoration of the labral seal was noted (*). A, acetabulum; FH, femoral head; G, graft.
Fibertak Anchor, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fibertak anchor/product/Arthrex Inc
Average 86 stars, based on 1 article reviews
fibertak anchor - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

86
Arthrex Inc fibertak soft anchors
The left hip of the same patient in after circumferential labral reconstruction using an allograft (G) and 1.8mm Knotless <t>FiberTak</t> anchors (Arthrex) to perform the knotless pull-through technique. View was from the anterolateral (12 o’clock) portal with a 70 arthroscope. (a) Under traction, the most medial point of fixation of the reconstruction site, was identified (M). (b) The arthroscope was moved laterally, the 12 o’clock position was identified (*). (c) Bird’s eye arthroscopic view of the fixated labral reconstruction graft (G). (d) Hip traction was released, restoration of the labral seal was noted (*). A, acetabulum; FH, femoral head; G, graft.
Fibertak Soft Anchors, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fibertak soft anchors/product/Arthrex Inc
Average 86 stars, based on 1 article reviews
fibertak soft anchors - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

86
Arthrex Inc fibertak anchors
The left hip of the same patient in after circumferential labral reconstruction using an allograft (G) and 1.8mm Knotless <t>FiberTak</t> anchors (Arthrex) to perform the knotless pull-through technique. View was from the anterolateral (12 o’clock) portal with a 70 arthroscope. (a) Under traction, the most medial point of fixation of the reconstruction site, was identified (M). (b) The arthroscope was moved laterally, the 12 o’clock position was identified (*). (c) Bird’s eye arthroscopic view of the fixated labral reconstruction graft (G). (d) Hip traction was released, restoration of the labral seal was noted (*). A, acetabulum; FH, femoral head; G, graft.
Fibertak Anchors, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fibertak anchors/product/Arthrex Inc
Average 86 stars, based on 1 article reviews
fibertak anchors - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

86
Arthrex Inc fibertak knotless anchors
The left hip of the same patient in after circumferential labral reconstruction using an allograft (G) and 1.8mm Knotless <t>FiberTak</t> anchors (Arthrex) to perform the knotless pull-through technique. View was from the anterolateral (12 o’clock) portal with a 70 arthroscope. (a) Under traction, the most medial point of fixation of the reconstruction site, was identified (M). (b) The arthroscope was moved laterally, the 12 o’clock position was identified (*). (c) Bird’s eye arthroscopic view of the fixated labral reconstruction graft (G). (d) Hip traction was released, restoration of the labral seal was noted (*). A, acetabulum; FH, femoral head; G, graft.
Fibertak Knotless Anchors, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fibertak knotless anchors/product/Arthrex Inc
Average 86 stars, based on 1 article reviews
fibertak knotless anchors - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

86
Arthrex Inc knotless fibertak soft anchors
The left hip of the same patient in after circumferential labral reconstruction using an allograft (G) and 1.8mm Knotless <t>FiberTak</t> anchors (Arthrex) to perform the knotless pull-through technique. View was from the anterolateral (12 o’clock) portal with a 70 arthroscope. (a) Under traction, the most medial point of fixation of the reconstruction site, was identified (M). (b) The arthroscope was moved laterally, the 12 o’clock position was identified (*). (c) Bird’s eye arthroscopic view of the fixated labral reconstruction graft (G). (d) Hip traction was released, restoration of the labral seal was noted (*). A, acetabulum; FH, femoral head; G, graft.
Knotless Fibertak Soft Anchors, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/knotless fibertak soft anchors/product/Arthrex Inc
Average 86 stars, based on 1 article reviews
knotless fibertak soft anchors - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

86
Arthrex Inc knotless fibertak rc anchors
Medial row anchor placement shown on a right cadaveric shoulder. Three 2.6-mm knotless <t>FiberTak</t> RC anchors (Arthrex) are placed approximately 1 cm apart for the medial row. Two or 3 medial row anchors may be used depending on tear size and morphology. If 3 anchors are used, the posterior medial row anchor SutureTape (Arthrex) is removed. (HH, humeral head; Ssp, supraspinatus tendon.)
Knotless Fibertak Rc Anchors, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/knotless fibertak rc anchors/product/Arthrex Inc
Average 86 stars, based on 1 article reviews
knotless fibertak rc anchors - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

86
Arthrex Inc double knotless fibertak suture anchors
Starting materials: FiberLink (Arthrex) passing suture, free needle, two 2.6-mm <t>FiberTak</t> (Arthrex) anchors, and 2.6-mm drill bit.
Double Knotless Fibertak Suture Anchors, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/double knotless fibertak suture anchors/product/Arthrex Inc
Average 86 stars, based on 1 article reviews
double knotless fibertak suture anchors - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

Image Search Results


The left hip of the same patient in after circumferential labral reconstruction using an allograft (G) and 1.8mm Knotless FiberTak anchors (Arthrex) to perform the knotless pull-through technique. View was from the anterolateral (12 o’clock) portal with a 70 arthroscope. (a) Under traction, the most medial point of fixation of the reconstruction site, was identified (M). (b) The arthroscope was moved laterally, the 12 o’clock position was identified (*). (c) Bird’s eye arthroscopic view of the fixated labral reconstruction graft (G). (d) Hip traction was released, restoration of the labral seal was noted (*). A, acetabulum; FH, femoral head; G, graft.

Journal: Journal of Hip Preservation Surgery

Article Title: High rate of graft integration after acetabular labral reconstruction with the knotless pull-through technique

doi: 10.1093/jhps/hnaf036

Figure Lengend Snippet: The left hip of the same patient in after circumferential labral reconstruction using an allograft (G) and 1.8mm Knotless FiberTak anchors (Arthrex) to perform the knotless pull-through technique. View was from the anterolateral (12 o’clock) portal with a 70 arthroscope. (a) Under traction, the most medial point of fixation of the reconstruction site, was identified (M). (b) The arthroscope was moved laterally, the 12 o’clock position was identified (*). (c) Bird’s eye arthroscopic view of the fixated labral reconstruction graft (G). (d) Hip traction was released, restoration of the labral seal was noted (*). A, acetabulum; FH, femoral head; G, graft.

Article Snippet: All reconstructions were done through the previously described pull-through technique utilizing a 2.9mm PushLock PEEK anchor (Arthrex, Inc., Naples, FL) to fix the most anterior part of the graft to the acetabular rim, followed by a Knotless SutureTak PEEK anchors (Arthrex) or 1.8mm Knotless FiberTak anchors (Arthrex) for a lower profile fixation ( ) [ ].

Techniques:

Medial row anchor placement shown on a right cadaveric shoulder. Three 2.6-mm knotless FiberTak RC anchors (Arthrex) are placed approximately 1 cm apart for the medial row. Two or 3 medial row anchors may be used depending on tear size and morphology. If 3 anchors are used, the posterior medial row anchor SutureTape (Arthrex) is removed. (HH, humeral head; Ssp, supraspinatus tendon.)

Journal: Arthroscopy Techniques

Article Title: The Double-Double Row: A Technique for Arthroscopic Rotator Cuff Repair

doi: 10.1016/j.eats.2025.103892

Figure Lengend Snippet: Medial row anchor placement shown on a right cadaveric shoulder. Three 2.6-mm knotless FiberTak RC anchors (Arthrex) are placed approximately 1 cm apart for the medial row. Two or 3 medial row anchors may be used depending on tear size and morphology. If 3 anchors are used, the posterior medial row anchor SutureTape (Arthrex) is removed. (HH, humeral head; Ssp, supraspinatus tendon.)

Article Snippet: First, two or three 2.6-mm knotless FiberTak RC anchors (Arthrex) are placed approximately 1 cm apart for the medial row, as shown in .

Techniques:

Starting materials: FiberLink (Arthrex) passing suture, free needle, two 2.6-mm FiberTak (Arthrex) anchors, and 2.6-mm drill bit.

Journal: Arthroscopy Techniques

Article Title: Distal Bicep Tendon Repair Utilizing Knotless Retensionable All-Suture Anchors

doi: 10.1016/j.eats.2025.103887

Figure Lengend Snippet: Starting materials: FiberLink (Arthrex) passing suture, free needle, two 2.6-mm FiberTak (Arthrex) anchors, and 2.6-mm drill bit.

Article Snippet: Two 2.6-mm hybrid and/or double knotless FiberTak suture anchors (Arthrex) are utilized in the proximal and distal aspects of the radial tuberosity ( ).

Techniques: